• Automatic measurements of left ventricular volumes and ejection fraction by artificial intelligence reduces time-consumption and inter-observer variability 

      Olaisen, Sindre Hellum; Espeland, Torvald; Smistad, Erik; Hu, Jieyu; Pasdeloup, David Francis Pierre; Østvik, Andreas; Amundsen, Brage H.; Aakhus, Svend; Rösner, Assami; Stylidis, Michael; Holte, Espen; Grenne, Bjørnar Leangen; Løvstakken, Lasse; Dalen, Håvard (Conference object; Konferansebidrag, 2023-06-19)
    • Automatic measurements of left ventricular volumes and ejection fraction by artificial intelligence: clinical validation in real time and large databases 

      Olaisen, Sindre Hellum; Smistad, Erik; Espeland, Torvald; Hu, Jieyu; Pasdeloup, David Francis Pierre; Østvik, Andreas; Aakhus, Svend; Rösner, Assami; Malm, Siri; Stylidis, Michael; Holte, Espen; Grenne, Bjørnar Leangen; Løvstakken, Lasse; Dalen, Håvard (Journal article; Tidsskriftartikkel; Peer reviewed, 2023-10-26)
      Aims - Echocardiography is a cornerstone in cardiac imaging, and left ventricular (LV) ejection fraction (EF) is a key parameter for patient management. Recent advances in artificial intelligence (AI) have enabled fully automatic measurements of LV volumes and EF both during scanning and in stored recordings. The aim of this study was to evaluate the impact of implementing AI measurements on acquisition ...
    • Increased complement factor B and Bb levels are associated with mortality in patients with severe aortic stenosis 

      Shahini, Negar; Ueland, Thor; Auensen, Andreas; Michelsen, Annika; Ludviksen, Judith K; Hussain, Amjad Iqbal; Pettersen, Kjell; Aakhus, Svend; Espeland, Torvald; Lunde, Ida Gjervold; Kirschfink, Michael; Nilsson, Per; Mollnes, Tom Eirik; Gullestad, Lars; Aukrust, Pål; Yndestad, Arne; Louwe, Maria Cornelia (Journal article; Tidsskriftartikkel; Peer reviewed, 2019-09-24)
      Inflammation is involved in initiation and progression of aortic stenosis (AS). However, the role of the complement system, a crucial component of innate immunity in AS, is unclear. We hypothesized that circulating levels of complement factor B (FB), an important component of the alternative pathway, are upregulated and could predict outcome in patients with severe symptomatic AS. Therefore, plasma ...
    • YKL-40 (Chitinase-3-Like Protein 1) Serum Levels in Aortic Stenosis 

      Arain, Fizza Kanwal; Abraityte, Judita Aurelija; Bogdanova, Mariia; Solberg, Ole Geir; Michelsen, Annika; Lekva, Tove; Aakhus, Svend; Holm, Sverre; Halvorsen, Bente; Finsen, Alexandra; Vinge, Leif Erik; Nymo, Ståle Haugset; Espeland, Torvald; Ranheim, Trine; Aukrust, Pål; Vaage, Ingvar Jarle; Auensen, Andreas; Gullestad, Lars; Ueland, Thor (Journal article; Tidsskriftartikkel; Peer reviewed, 2020-09-23)
      <p><i>Background:</i> Identification of novel biomarkers could provide prognostic information and improve risk stratification in patients with aortic stenosis (AS). YKL-40 (chitinase-3-like protein 1), a protein involved in atherogenesis, is upregulated in human calcific aortic valves. We hypothesized that circulating YKL-40 would be elevated and associated with the degree of AS severity and outcome ...